Release 10.1A: OpenEdge Data Management:
Database Administration
Startup Parameters
Displays values of OpenEdge database startup parameters. Figure 19–27 shows a sample Startup Parameters Status display.
Figure 19–27: PROMON Startup Parameters Status display
The display contains the following fields:
- Maximum clients — The value of the Number of Users (-
n) parameter.- Maximum servers — The value of the Maximum Servers (-
mn) parameter.- Maximum clients per server — The value of the Maximum Clients per Server (-
Ma) parameter.- Lock table size — The value of the Lock Table Entries (-
L) parameter.- Database buffers — The value of the Blocks in Database Buffers (-
B) parameter.- APW queue check time — The value of the Page Writer Queue Delay (-
pwqdelay) parameter.- APW scan time — The value of the Page Writer Scan Delay (-
pwsdelay) parameter.- APW buffers to scan — The value of the Page Writer Scan (-
pwscan) parameter.- APW max writes/scan — The value of the Page Writer Maximum Buffers (-
pwwmax) parameter.- Spinlock tries before timeout — The number of times a process will spin (
-spin) trying to acquire a resource before waiting.- Before-image buffers — The value of the Before-image Buffers (-
bibufs) parameter.- After-image buffers — The value of the After-image Buffers (-
aibufs) parameter.- Max number of JTA transactions — The value of the Maximum JTA Transaction Ids (
-maxxids) parameter.
|